Brand Name : xinje
Model Number : XD3-22T4TC-E
Certification : CCC
Place of Origin : CHINA
MOQ : 1
Price : $98-110/pc
Payment Terms : L/C, T/T, Western Union
Supply Ability : 1000/PC/MONTH
Delivery Time : 14 Work days
Packaging Details : Carton (standard original package)
Processing speed : 0.02~0.05us
User program capacity ※1 : 256kB
Control precision : ±0.5℃
Resolution : 0.1℃
Comprehensive accuracy : 1%(Relative maximum)
Conversion speed : 80ms/1 channel
XD3 series special model integrates logic control and thermocouple input. Digital value input: 8 points (NPN optocoupler isolation), digital value output: 14 points (transistor type); thermocouple signal input: 4 points
Product features
XD3 series special model integrates logic control and thermocouple input.
Digital value input: 8 points (NPN optocoupler isolation), digital value output: 14 points (transistor type)
Thermocouple signal input: 4 points
Power specification: AC220V
Support 2 channels of AB phase input
Support 2 channels of high-speed counting (10kHz)
Support MODBUS and X-NET communication
High cost performance, greatly saving space
Model list
Model | Function |
XD3-22T4TC-E | 8-channel NPN type digital value input, 14-channel transistor output, 4-channel thermocouple signal input |
Function table
Series | USB port | RS232 port | RS485 | Free communication | Extension module | Extension BD | Left extension ED | High speed counting channel | Pulse output | External interrupt | |
Increase mode | AB phase | ||||||||||
XD3-22T4TC | × | 2 | √ | √ | × | × | × | 2 | 2 | 2 | 6 |
General Specifications
Functional Specifications
|
Notes:
※ 1: User program capacity refers to the maximum program capacity during secret download.
※ 2: I / O points refer to the number of terminals that users can access and output signals from the outside.
※ 3: X refers to the internal input relay, and X exceeding I points can be used as intermediate relay.
※ 4: y refers to the internal output relay. Y exceeding O points can be used as an intermediate relay.
※ 5: [ ] flag, which is the default power-off holding area and cannot be changed.
※ 6: Special use refers to the special purpose register occupied by the system, which can not be used for other purposes.
※ 7: The numbers of input coils and output relays / transistors are octal numbers, and the numbers of other memories are decimal numbers.
※ 8: I / O without real connection with peripheral equipment can be used as fast internal relay.
Function configuration table:
Item | Contents | |
Analog input | K, S, E, N, B, T, J, R types of thermocouple | |
Measuring temperature range | Type K | 0℃~1300℃ |
Type S | 0℃~1700℃ | |
Type E | 0℃~600℃ | |
Type N | 0℃~1200℃ | |
Type B | 0℃~1800℃ (display 0 below 250℃) | |
Type T | 0℃~400℃ | |
Type J | 0℃~800℃ | |
Type R | 0℃~1700℃ | |
Digital output range | 0~max measuring temperature value ×10 (take type K as an example, the digital output range is 0~13000) Signed 16 bits, binary | |
Control precision | ±0.5℃ | |
Resolution | 0.1℃ | |
Comprehensive accuracy | 1%(Relative maximum) | |
Conversion speed | 80ms/1 channel |
Note:
(1) When there is no signal input, the channel data is - 1.
(2) Connect thermocouples according to actual needs.
(3) The enclosure of the equipment installed by the thermocouple must be grounded.
![]() |