| Connection |   			Connec |   			
  			roduct characteristics |   			Number of inputs and outputs |   			Number of digital outputs: 2; Number of analog outputs: 1 |   			Measuring range |   			  			  				  					  					  					  				  				  					  						| 0...250 bar |   						0...3625 psi |   						0...25 MPa |   					   				  			   			 |   			Process connection |   			threaded connection G 1/4 Internal thread (DIN EN ISO 1179-2) |   			Application |   			System |   			gold-plated contacts |   			Measuring element |   			metallic thin film cell |   			Application |   			for industrial applications |   			Media |   			liquids and gases |   			Medium temperature [°C] |   			-25...80 |   			Min. bursting pressure |   			  			  				  					  					  					  				  				  					  						| 1200 bar |   						17400 psi |   						120 MPa |   					   				  			   			 |   			Pressure rating |   			  			  			 |   			Vacuum resistance [mbar] |   			-1000 |   			Type of pressure |   			relative pressure |   			Electrical data |   			Operating voltage [V] |   			18...30 DC; (to SELV/PELV) |   			Current consumption [mA] |   			< 35 |   			Min. insulation resistance [MΩ] |   			100; (500 V DC) |   			Protection class |   			III |   			Reverse polarity protection |   			yes |   			Power-on delay time [s] |   			0.3 |   			Integrated watchdog |   			yes |   			Inputs / outputs |   			Number of inputs and outputs |   			Number of digital outputs: 2; Number of analog outputs: 1 |   			Outputs |   			Total number of outputs |   			2 |   			Output signal |   			switching signal; analog signal; IO-Link; (configurable) |   			Electrical design |   			PNP/NPN |   			Number of digital outputs |   			2 |   			Output function |   			normally open / closed; (configurable) |   			Max. voltage drop switching output DC [V] |   			2 |   			Permanent current rating of switching output DC [mA] |   			250 |   			Switching frequency DC [Hz] |   			< 500 |   			Number of analog outputs |   			1 |   			Analog current output [mA] |   			4...20; (scalable 1:5) |   			Max. load [Ω] |   			500 |   			Analog voltage output [V] |   			0...10; (scalable 1:5) |   			Min. load resistance [Ω] |   			2000 |   			Short-circuit protection |   			yes |   			Type of short-circuit protection |   			yes (non-latching) |   			Overload protection |   			yes |   			Measuring/setting range |   			Measuring range |   			  			  				  					  					  					  				  				  					  						| 0...250 bar |   						0...3625 psi |   						0...25 MPa |   					   				  			   			 |   			Analog start point |   			  			  				  					  					  					  				  				  					  						| 0...200 bar |   						0...2900 psi |   						0...20 MPa |   					   				  			   			 |   			Analog end point |   			  			  				  					  					  					  				  				  					  						| 50...250 bar |   						725...3625 psi |   						5...25 MPa |   					   				  			   			 |   			Factory setting / CMPT = 2 |   			Set point SP |   			  			  				  					  					  					  				  				  					  						| 1.5...250 bar |   						25...3625 psi |   						0.15...25 MPa |   					   				  			   			 |   			Reset point rP |   			  			  				  					  					  					  				  				  					  						| 0.5...249 bar |   						10...3610 psi |   						0.05...24.9 MPa |   					   				  			   			 |   			Min. difference between SP and rP |   			  			  			 |   			In steps of |   			  			  			 |   			Status_B High Resolution / CMPT = 3 |   			Set point SP |   			  			  				  					  					  					  				  				  					  						| 1.6...250 bar |   						23...3626 psi |   						0.16...25 MPa |   					   				  			   			 |   			Reset point rP |   			  			  				  					  					  					  				  				  					  						| 0.5...249 bar |   						8...3611 psi |   						0.05...24.9 MPa |   					   				  			   			 |   			Min. difference between SP and rP |   			  			  			 |   			In steps of |   			  			  			 |   			Accuracy / deviations |   			Switch point accuracy [% of the span] |   			< ± 0,4; (Turn down 1:1) |   			Repeatability [% of the span] |   			< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |   			Characteristics deviation [% of the span] |   			< ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting) |   			Hysteresis deviation [% of the span] |   			< ± 0,1; (Turn down 1:1) |   			Long-term stability [% of the span] |   			< ± 0,05; (Turn down 1:1; per 6 months) |   			Temperature coefficient zero point [% of the span / 10 K] |   			0,2; (-25...80 °C) |   			Temperature coefficient span [% of the span / 10 K] |   			0,2; (-25...80 °C) |   			Notes on the accuracy / deviation |   			switch point accuracy, linearity error under DNV GL: < ± 1%: < ± 1% |   			Reaction times |   			Response time [ms] |   			< 1.5 |   			Delay time programmable dS, dr [s] |   			0...50 |   			Damping process value dAP [s] |   			0...4 |   			Damping for the analog output dAA [s] |   			0...4 |   			Max. response time analog output [ms] |   			3 |   			Software / programming |   			Parameter setting options |   			hysteresis / window; normally open / closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output |   			Interfaces |   			Communication interface |   			IO-Link |   			Transmission type |   			COM2 (38,4 kBaud) |   			IO-Link revision |   			1.1 |   			SDCI standard |   			IEC 61131-9 |   			SIO mode |   			yes |   			Required master port class |   			A; (when pin 2 not connected: B) |   			Supported DeviceIDs |   			  			  				  					  					  				  				  					  						| Type of operation |   						DeviceID |   					   					  						| Factory setting / CMPT = 2 |   						460 |   					   					  						| Status_B High Resolution / CMPT = 3 |   						639 |   					   				  			   			 |   			Note |   			  			  				  					  				  				  					  						| For further information please see the IODD PDF file at "Downloads" |   					   				  			   			 |   			Factory setting / CMPT = 2 |   			Profiles |   			Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |   			Min. process cycle time [ms] |   			2.3 |   			IO-Link resolution pressure [bar] |   			0.1 |   			IO-Link process data (cyclical) |   			  			  				  					  					  				  				  					  						| Function |   						bit length |   					   					  						| pressure |   						14 |   					   					  						| binary switching information |   						2 |   					   				  			   			 |   			IO-Link functions (acyclical) |   			application specific tag |   			Status_B High Resolution / CMPT = 3 |   			Profiles |   			Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000) |   			Min. process cycle time [ms] |   			3 |   			IO-Link resolution pressure [bar] |   			0.1 |   			IO-Link process data (cyclical) |   			  			  				  					  					  				  				  					  						| Function |   						bit length |   					   					  						| pressure |   						16 |   					   					  						| device status |   						4 |   					   					  						| binary switching information |   						2 |   					   				  			   			 |   			IO-Link functions (acyclical) |   			application specific tag |   			Operating conditions |   			Ambient temperature [°C] |   			-25...80 |   			Storage temperature [°C] |   			-40...100 |   			Protection |   			IP 65; IP 67 |   			Tests / approvals |   			EMC |   			  			  				  					  					  				  				  					  						| DIN EN 61000-6-2 |   						  |   					   					  						| DIN EN 61000-6-3 |   						  |   					   				  			   			 |   			Shock resistance |   			  			  				  					  					  				  				  					  						| DIN EN 60068-2-27 |   						50 g (11 ms) |   					   				  			   			 |   			Vibration resistance |   			  			  				  					  					  				  				  					  						| DIN EN 60068-2-6 |   						20 g (10...2000 Hz) |   					   				  			   			 |   			MTTF [years] |   			129 |   			UL approval |   			  			  			 |   			Pressure equipment directive |   			sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |   			Mechanical data |   			Weight [g] |   			234.5 |   			Housing |   			tubular |   			Dimensions [mm] |   			Ø 34 / L = 90.7 |   			Material |   			stainless steel (630/1.4542/17-4 PH); stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC |   			Materials (wetted parts) |   			stainless steel (630/1.4542/17-4 PH) |   			Min. pressure cycles |   			100 million |   			Tightening torque [Nm] |   			25...35; (recommended tightening torque; Depends on lubrication, seal and pressure rating) |   			Process connection |   			threaded connection G 1/4 Internal thread (DIN EN ISO 1179-2) |   			Restrictor element integrated |   			no (can be retrofitted) |   			Displays / operating elements |   			Display |   			  			  				  					  					  				  				  					  						| Display unit |   						3 x LED, green (bar, psi, MPa) |   					   					  						| Switching status |   						2 x LED, yellow |   					   					  						| Measured values |   						alphanumeric display, red/green 4-digit |   					   				  			   			 |   			Remarks |   			Pack quantity |   			1 pcs. |   			Electrical connection |   			Connection |   			Connec      |